The system is coming up, please wait... U-Boot 1.1.3 (Jun 25 2014 - 10:28:11) CPU: AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz) No Security/Kasumi support I2C boot EEPROM enabled Bootstrap Option G - Boot ROM Location I2C (Addr 0x54) Internal PCI arbiter enabled, PCI async ext clock used 32 kB I-Cache 32 kB D-Cache Board: Tomtoo I2C: ready DRAM: Initializing DDRSDRAM DQS calibration - Window detected: max_passing_cases = 52 wr_dqs_shift = 94 dll_dqs_delay_X = 29 dll_dqs_delay_X window = 4 - 55 DDR0_09=0x00011d5e DDR0_22=0x03267e0b DDR0_17=0x1d005c00 DDR0_18=0x1d1d1d1d DDR0_19=0x1d1d1d1d Zeroing SDRAM... DONE DDR: 1024 MB POST RAM test disabled. Now running in RAM - U-Boot at: 3fb29000 trap_init : 0x0 system inventory subsystem initialized FLASH: Tomtoo CFI Flash Driver Initialized 4 MB DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x03... CPLD: Reseting Bridge ASIC... ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec PCI: Skip our host bridge 01 00 1657 001d 0280 1a 00 07 10b5 8112 0604 18 In: serial Out: serial Err: serial Net: Checking system RAM - press any key to stop test Checking memory address: 00100000 System RAM test using Default POST RAM Test succeeded. set_bootstatus: BS_LOAD_OS, platform_idx = 16 Type run flash_nfs to mount root filesystem over NFS Hit ESC to stop autoboot: 0 Map file at LBA sector 0xc792f ## Booting image at 00400000 ... Image Name: Linux-2.6.14.2 Image Type: PowerPC Linux Multi-File Image (uncompressed) Data Size: 4290075 Bytes = 4.1 MB Load Address: 00000000 Entry Point: 00000000 Contents: Image 0: 3211397 Bytes = 3.1 MB Image 1: 1078663 Bytes = 1 MB ## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000 ## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587) Loading Ramdisk to 1fef8000, end 1ffff587 ... OK initrd_start = 1fef8000, initrd_end = 1ffff587 ## Transferring control to Linux (at address 00000000) ... Start Autoneg Installing Linux 2.6 Kernel Attempting to find a root file system on hda1... INIT: version 2.78 booting Bypassing firmware validation. INIT: Entering runlevel: 3 Starting Fabric OS Services... FIPS off, RRD... Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold) sys_chip_init: class 0 max 24 Done ethsw_ha_enabled = 1 uptime: 4293889063; sup_qid: 0 . 2015/07/15-20:56:24, [HAM-1004], 2, CHASSIS, INFO, Brocade6505, Processor rebooted - Reset. Fabric OS (SW6505) SW6505 console login: 2015/07/15-20:56:36, [FV-1001], 3, CHASSIS, INFO, SW6505, Flow Vision daemon initialized. SNMP Research EMANATE/Lite Agent Version 16.2.0.9 Copyright 1989-2006 SNMP Research, Inc. ki_state_set: redundant ACTIVATE for instance 1 2015/07/15-20:56:47, [FV-1002], 4, FID 128, INFO, SW6505, Flow Vision Config Replay Completed Successfully. Jul 15 20:56:49 All service instances on Active 2015/07/15-20:56:52, [EM-1049], 5, CHASSIS, INFO, Brocade6505, FRU Fan 1 insertion detected. 2015/07/15-20:56:52, [EM-1049], 6, CHASSIS, INFO, Brocade6505, FRU PS 1 insertion detected. POST1: Started running Wed Jul 15 20:56:53 GMT 2015 POST1: Test #1 - Running turboramtest POST1: Script PASSED with exit status of 0 Wed Jul 15 20:57:12 GMT 2015 took (0:0:19) POST2: Started running Wed Jul 15 20:57:14 GMT 2015 POST2: Test #1 - Running portloopbacktest (SERDES) POST2: Script PASSED with exit status of 0 Wed Jul 15 20:57:43 GMT 2015 took (0:0:29) 2015/07/15-20:57:44, [BL-1000], 7, CHASSIS, INFO, Brocade6505, Initializing ports... 2015/07/15-20:57:44, [BL-1001], 8, CHASSIS, INFO, Brocade6505, Port initialization completed. 2015/07/15-20:59:39, [IPAD-1001], 9, CHASSIS, INFO, Brocade6505, CP/0 IPv6 autoconf fe80::5:73ff:fea0:2 DHCP not Set. Fabric OS (SW6505) |
SW6505 console login: root Password: Disclaimer for Root and Factory Accounts Usage! Warning: Access to the Root and Factory accounts may be required for proper support of the switch. Please ensure the Root and Factory passwords are documented in a secure location. Recovery of a lost Root or Factory password will result in fabric downtime. for user - root Changing password for root Enter new password: <--- type new password Re-type new password: <--- type new password passwd: all authentication tokens updated successfully Please change passwords for switch default accounts now. for user - factory Changing password for factory Enter new password: <--- type new password Re-type new password: <--- type new password passwd: all authentication tokens updated successfully Please change passwords for switch default accounts now. for user - admin Changing password for admin Enter new password: <--- type new password Re-type new password: <--- type new password passwd: all authentication tokens updated successfully Please change passwords for switch default accounts now. for user - user Changing password for user Enter new password: <--- type new password Re-type new password: <--- type new password passwd: all authentication tokens updated successfully Saving passwords to stable storage. Passwords saved to stable storage successfully |
SW6505:root> switchname SW6505 SW6505:root> switchname 5-zz-1 Committing configuration... Done. Switch name has been changed.Please re-login into the switch for the change to be applied. 2015/07/15-21:05:06, [IPAD-1002], 10, FID 128, INFO, 5-zz-1, Switch name has been successfully changed to 5-zz-1. SW6505:root> switchname 5-zz-1 |
SW6505:root> tstimezone US/Pacific System Time Zone change will take effect at next reboot |
SW6505:root> ipaddrset Ethernet IP Address [10.77.77.77]:1xx.25.10.56 Ethernet Subnetmask [255.255.255.0]:255.255.254.0 Gateway IP Address [none]:1xx.25.10.1 DHCP [Off]: IP address is being changed...Done. [IPAD-1000], 11, CHASSIS, INFO, Brocade6505, SW/0 Ether/0 IPv4 manual 1xx.25.10.56/23 DHCP Off. [IPAD-1001], 12, CHASSIS, INFO, Brocade6505, CP/0 IPv4 manual 144.25.10.1 DHCP Off. SW6505:root> [SEC-1203], 13, FID 128, INFO, Login successful via TELNET/SSH/RSH. IP Addr: 1xx.25.12.136 |
SW6505:root> reboot Warning: This command would cause the switch to reboot and result in traffic disruption. Are you sure you want to reboot the switch [y/n]?y 2015/07/15-14:08:18, [RAS-1007], 14, CHASSIS, INFO, Brocade6505, System is about to reboot. Broadcast message from root (ttyS0) Wed Jul 15 14:08:21 2015... The system is going down for reboot NOW !! INIT: Switching to runlevel: 6 INIT: Sending processes the TERM signal SW6505:root> chassis:0-lfm: Image-incomplete event ##RSCMON exiting due to signal: 19, pending signals: 0x0, 0x0 ##exiting due to signal: 19, pending signals: 0x0, 0x0 Stopping diagnostics Unmounting all filesystems. Please stand by while rebooting the system... Restarting system. . The system is coming up, please wait... Fabric OS (5-zz-1) 5-zz-1 console login: |
5-zz-1:admin> switchshow switchName: 5-zz-1 switchType: 118.1 switchState: Online switchMode: Native switchRole: Principal switchDomain: 1 switchId: fffc01 switchWwn: 10:00:50:eb:1a:86:75:17 zoning: OFF switchBeacon: OFF FC Router: OFF FC Router BB Fabric ID: 1 Address Mode: 0 Index Port Address Media Speed State Proto ================================================== 0 0 010000 -- N16 No_Module FC 1 1 010100 -- N16 No_Module FC 2 2 010200 -- N16 No_Module FC 3 3 010300 -- N16 No_Module FC 4 4 010400 -- N16 No_Module FC 5 5 010500 -- N16 No_Module FC 6 6 010600 id N8 Online FC F-Port 20:11:00:02:ac:00:2c:66 7 7 010700 id N8 Online FC F-Port 21:11:00:02:ac:00:2c:66 8 8 010800 id N16 Online FC F-Port 10:00:c4:34:6b:20:05:8d 9 9 010900 id N16 Online FC F-Port 10:00:c4:34:6b:20:05:8c 10 10 010a00 id N16 Online FC F-Port 50:01:43:80:23:1d:ef:62 11 11 010b00 id N16 Online FC F-Port 50:01:43:80:23:1d:ef:60 12 12 010c00 id N16 Online FC F-Port 10:00:c4:34:6b:20:15:e5 13 13 010d00 id N16 Online FC F-Port 10:00:c4:34:6b:20:15:e4 14 14 010e00 id N16 Online FC F-Port 50:01:43:80:23:1d:ef:6e 15 15 010f00 id N16 Online FC F-Port 50:01:43:80:23:1d:ef:6c 16 16 011000 -- N16 No_Module FC 17 17 011100 -- N16 No_Module FC 18 18 011200 -- N16 No_Module FC 19 19 011300 -- N16 No_Module FC 20 20 011400 -- N16 No_Module FC 21 21 011500 -- N16 No_Module FC 22 22 011600 -- N16 No_Module FC 23 23 011700 -- N16 No_Module FC |