Back to the main page

Brocade6505 FC switch initial setup

Connect to the serial console and power on the Brocade FC switch
The system is coming up, please wait...

U-Boot 1.1.3 (Jun 25 2014 - 10:28:11)
CPU:   AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
       No Security/Kasumi support
       I2C boot EEPROM enabled
       Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
       Internal PCI arbiter enabled, PCI async ext clock used
       32 kB I-Cache 32 kB D-Cache
Board: Tomtoo
I2C:   ready
DRAM:  Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 52
wr_dqs_shift      = 94
dll_dqs_delay_X   = 29
dll_dqs_delay_X window = 4 - 55
DDR0_09=0x00011d5e
DDR0_22=0x03267e0b
DDR0_17=0x1d005c00
DDR0_18=0x1d1d1d1d
DDR0_19=0x1d1d1d1d
Zeroing SDRAM...   DONE
    DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb29000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Tomtoo CFI Flash Driver Initialized
 4 MB

DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x03...

CPLD: Reseting Bridge ASIC...
ATA interface setup: io_base=0xf8f00000, port=0x3e0, ctl=0x7ec
PCI:
Skip our host bridge
        01  00  1657  001d  0280  1a
        00  07  10b5  8112  0604  18
In:    serial
Out:   serial
Err:   serial
Net:

Checking system RAM - press any key to stop test
Checking memory address: 00100000
System RAM test using Default POST RAM Test succeeded.
set_bootstatus: BS_LOAD_OS, platform_idx = 16
Type run flash_nfs to mount root filesystem over NFS
Hit ESC to stop autoboot:  0
Map file at LBA sector 0xc792f
## Booting image at 00400000 ...
   Image Name:   Linux-2.6.14.2
   Image Type:   PowerPC Linux Multi-File Image (uncompressed)
   Data Size:    4290075 Bytes =  4.1 MB
   Load Address: 00000000
   Entry Point:  00000000
   Contents:
   Image 0:  3211397 Bytes =  3.1 MB
   Image 1:  1078663 Bytes =  1 MB
## Current stack ends at 0x3FAE7BD8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
   Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
 initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda1...
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 1(threshold 5) abnormal reboots within 3000 seconds window(threshold)

sys_chip_init: class 0 max 24 Done
ethsw_ha_enabled = 1
uptime: 4293889063; sup_qid: 0
.
2015/07/15-20:56:24, [HAM-1004], 2, CHASSIS, INFO, Brocade6505, Processor rebooted - Reset.

Fabric OS (SW6505)

SW6505 console login: 2015/07/15-20:56:36, [FV-1001], 3, CHASSIS, INFO, SW6505, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2015/07/15-20:56:47, [FV-1002], 4, FID 128, INFO, SW6505, Flow Vision Config Replay Completed Successfully.
Jul 15 20:56:49  All service instances on Active
2015/07/15-20:56:52, [EM-1049], 5, CHASSIS, INFO, Brocade6505, FRU Fan 1 insertion detected.
2015/07/15-20:56:52, [EM-1049], 6, CHASSIS, INFO, Brocade6505, FRU PS 1 insertion detected.
POST1: Started running Wed Jul 15 20:56:53 GMT 2015
POST1: Test #1 - Running turboramtest
POST1: Script PASSED with exit status of 0 Wed Jul 15 20:57:12 GMT 2015 took (0:0:19)
POST2: Started running Wed Jul 15 20:57:14 GMT 2015
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Script PASSED with exit status of 0 Wed Jul 15 20:57:43 GMT 2015 took (0:0:29)
2015/07/15-20:57:44, [BL-1000], 7, CHASSIS, INFO, Brocade6505, Initializing ports...
2015/07/15-20:57:44, [BL-1001], 8, CHASSIS, INFO, Brocade6505, Port initialization completed.
2015/07/15-20:59:39, [IPAD-1001], 9, CHASSIS, INFO, Brocade6505, CP/0 IPv6 autoconf fe80::5:73ff:fea0:2 DHCP not Set.
Fabric OS (SW6505)
Now you are at the login prompt, setup password for all accounts ...
SW6505 console login: root
Password:
Disclaimer for Root and Factory Accounts Usage!

Warning:  Access to  the Root  and Factory accounts may be required  for
proper  support  of  the switch.  Please  ensure  the Root  and  Factory
passwords are  documented in a secure location.  Recovery of a lost Root
or Factory password will result in fabric downtime.

for user - root
Changing password for root
Enter new password: <--- type new password 
Re-type new password:  <--- type new password 
passwd: all authentication tokens updated successfully
Please change passwords for switch default accounts now.
for user - factory
Changing password for factory
Enter new password:  <--- type new password 
Re-type new password:  <--- type new password 
passwd: all authentication tokens updated successfully
Please change passwords for switch default accounts now.
for user - admin
Changing password for admin
Enter new password:  <--- type new password 
Re-type new password:  <--- type new password 
passwd: all authentication tokens updated successfully
Please change passwords for switch default accounts now.
for user - user
Changing password for user
Enter new password:  <--- type new password 
Re-type new password:  <--- type new password 
passwd: all authentication tokens updated successfully
Saving passwords to stable storage.
Passwords saved to stable storage successfully
Now change the switch name
SW6505:root> switchname
SW6505
SW6505:root> switchname 5-zz-1
Committing configuration...
Done.
Switch name has been changed.Please re-login into the switch for the change to be applied.
2015/07/15-21:05:06, [IPAD-1002], 10, FID 128, INFO, 5-zz-1, Switch name has been successfully changed to 5-zz-1.
SW6505:root> switchname
5-zz-1
Change the timezone
SW6505:root> tstimezone US/Pacific
System Time Zone change will take effect at next reboot
Setup an IP
SW6505:root> ipaddrset
Ethernet IP Address [10.77.77.77]:1xx.25.10.56
Ethernet Subnetmask [255.255.255.0]:255.255.254.0
Gateway IP Address [none]:1xx.25.10.1
DHCP [Off]:
IP address is being changed...Done.
[IPAD-1000], 11, CHASSIS, INFO, Brocade6505, SW/0 Ether/0 IPv4 manual 1xx.25.10.56/23 DHCP Off.
[IPAD-1001], 12, CHASSIS, INFO, Brocade6505, CP/0 IPv4 manual 144.25.10.1 DHCP Off.
SW6505:root> [SEC-1203], 13, FID 128, INFO, Login successful via TELNET/SSH/RSH. IP Addr: 1xx.25.12.136
Reboot the switch
SW6505:root> reboot 
Warning: This command would cause the switch to reboot
and result in traffic disruption.
Are you sure you want to reboot the switch [y/n]?y
2015/07/15-14:08:18, [RAS-1007], 14, CHASSIS, INFO, Brocade6505, System is about to reboot.

Broadcast message from root (ttyS0) Wed Jul 15 14:08:21 2015...

The system is going down for reboot NOW !!
INIT: Switching to runlevel: 6
INIT: Sending processes the TERM signal
SW6505:root> chassis:0-lfm: Image-incomplete event
##RSCMON exiting due to signal: 19, pending signals: 0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Unmounting all filesystems.
Please stand by while rebooting the system...
Restarting system.
.
The system is coming up, please wait...
Fabric OS (5-zz-1)
5-zz-1 console login: 
After adding come fc connections (8g and 16g), check the results
5-zz-1:admin> switchshow
switchName:     5-zz-1
switchType:     118.1
switchState:    Online
switchMode:     Native
switchRole:     Principal
switchDomain:   1
switchId:       fffc01
switchWwn:      10:00:50:eb:1a:86:75:17
zoning:         OFF
switchBeacon:   OFF
FC Router:      OFF
FC Router BB Fabric ID: 1
Address Mode:   0

Index Port Address Media Speed       State   Proto
==================================================
   0   0   010000   --    N16      No_Module   FC
   1   1   010100   --    N16      No_Module   FC
   2   2   010200   --    N16      No_Module   FC
   3   3   010300   --    N16      No_Module   FC
   4   4   010400   --    N16      No_Module   FC
   5   5   010500   --    N16      No_Module   FC
   6   6   010600   id    N8       Online      FC  F-Port  20:11:00:02:ac:00:2c:66
   7   7   010700   id    N8       Online      FC  F-Port  21:11:00:02:ac:00:2c:66
   8   8   010800   id    N16      Online      FC  F-Port  10:00:c4:34:6b:20:05:8d
   9   9   010900   id    N16      Online      FC  F-Port  10:00:c4:34:6b:20:05:8c
  10  10   010a00   id    N16      Online      FC  F-Port  50:01:43:80:23:1d:ef:62
  11  11   010b00   id    N16      Online      FC  F-Port  50:01:43:80:23:1d:ef:60
  12  12   010c00   id    N16      Online      FC  F-Port  10:00:c4:34:6b:20:15:e5
  13  13   010d00   id    N16      Online      FC  F-Port  10:00:c4:34:6b:20:15:e4
  14  14   010e00   id    N16      Online      FC  F-Port  50:01:43:80:23:1d:ef:6e
  15  15   010f00   id    N16      Online      FC  F-Port  50:01:43:80:23:1d:ef:6c
  16  16   011000   --    N16      No_Module   FC
  17  17   011100   --    N16      No_Module   FC
  18  18   011200   --    N16      No_Module   FC
  19  19   011300   --    N16      No_Module   FC
  20  20   011400   --    N16      No_Module   FC
  21  21   011500   --    N16      No_Module   FC
  22  22   011600   --    N16      No_Module   FC
  23  23   011700   --    N16      No_Module   FC

The FC switch can be added to Observium also.


Back to the main page