Back to the main page

StorEdge 3000 family of software

Beside using old fashion GUI, the FC StorEdge 3510 can be also managed with The Sun StorEdge 3000 family of software. 
Actually this family is one package: Sun Storage[TM] Configuration Service package (SUNWsscs).

When writing this, the SUNWsscs version is 2.4.
 
This version is for use with Sun StorEdge 3510 FC arrays running firmware version 4.2, but can be also used with older firmware except some functionality will not work. 
The SUNWsscs includes the following components:
- Sun StorEdge Configuration Service agent
- Sun StorEdge Configuration Service console
- Sun StorEdge Diagnostic Reporter agent (daemon)
- Sun StorEdge Diagnostic Reporter Config Tool (UI)
- Sun StorEdge Command-Line Interface (CLI)

Tip: 
Diagnostic Reporter connects to Configuration Service Agent and receives any event from the Agent. 
If  the event is assigned a trap condition, Diagnostic Reporter emails the event to a user. 

Get the file 2.4_sw_solaris-sparc.zip from Sun Downloads . 
It's behind the link "StorageTek 3000 Family Storage Products--Related Software 2.4" 

Unzip it and install the package. 

# /tmp/solaris/sparc> pkgadd -d . SUNWsscs

-- output --
## Executing postinstall script.
Using uid 60000 for username ssmon.
Using uid 59999 for username ssadmin.
Using uid 59998 for username ssconfig.
Be sure to set the passwords for all SSCS users(ssmon,ssadmin,ssconfig).

Before starting the Console, please run
/opt/SUNWsscs/sscsconsole/config_sscon to specify the web browser
to use for accessing online help.

The Sun StorEdge Configuration Service agent and Sun StorEdge Diagnostic
Reporter daemon have been installed, but are not configured to start at boot
time by default.

To enable the Sun StorEdge Configuration Service agent to start automatically
when the system boots, and to start it now, type:

/etc/init.d/ssagent enable start

To enable the Sun StorEdge Diagnostic Reporter to start automatically when the
system boots, and to start it now, type:

/etc/init.d/ssdgrptd enable start

Refer to the Sun StorEdge 3000 Family Software Installation Guide for more
information.
Installation of  was successful.
So far I have been using only StorEdge Command-Line Interface (CLI). Below are some most used commands ("show ones") and for now I will not write more about this here.
# /opt/SUNWsscs/sbin> ./sccli
sccli: selected device /dev/rdsk/c2t40d0s2 [SUN StorEdge 3510 SN#09CACC]
sccli>
sccli> version
sccli version 2.4.0
sccli> show rs232-configuration
 COM1 speed: 38400bps

Note: I am using console appliance Cyclades and its file /etc/portslave/pslave.conf has below lines. 
s20.tty ttyS20
s20.speed       38400
sccli> show ses-devices
Ch  Id Chassis Vendor/Product ID        Rev  PLD  WWNN             WWPN
-------------------------------------------------------------------------------
 2  44 0983DA  SUN StorEdge 3510F A     1103 1000 204000C0FF0983DA 214000C0FF0983DA
                                                     Topology: loop(a)
 3  44 0983DA  SUN StorEdge 3510F A     1103 1000 204000C0FF0983DA 224000C0FF0983DA
                                                     Topology: loop(b)
sccli> show access-mode
 access-mode: inband
sccli> show battery-status
 Upper Battery Type: 1
 Upper Battery Manufacturing Date: Sun Oct 12 00:00:00 2008
 Upper Battery Placed In Service:  Wed Apr 15 22:04:03 2009
 Upper Battery Expiration Date:    Sat Apr 16 10:04:03 2011
 Upper Battery Expiration Status:  OK

 Lower Battery Type: 1
 Lower Battery Manufacturing Date: Sun Oct 12 00:00:00 2008
 Lower Battery Placed In Service:  Fri Apr 17 22:53:50 2009
 Lower Battery Expiration Date:    Mon Apr 18 10:53:50 2011
 Lower Battery Expiration Status:  OK
---------------------------------------------------------------
 Upper Battery Hardware Status:    OK
 Lower Battery Hardware Status:    OK
sccli> show channels
Ch  Type    Media   Speed   Width  PID / SID
--------------------------------------------
 0  Host    FC(L)   2G      Serial  40 / 41
 1  Host    FC(L)   N/A     Serial  N/A / 42
 2  DRV+RCC FC(L)   2G      Serial  14 / 15
 3  DRV+RCC FC(L)   2G      Serial  14 / 15
 4  Host    FC(L)   2G      Serial  44 / N/A
 5  Host    FC(L)   2G      Serial  47 / 46
 6  Host    LAN     N/A     Serial  N/A / N/A
sccli> show configuration
Sun StorEdge 3000 Family CLI
Copyright 2002-2007 Dot Hill Systems Corporation.
All rights reserved. Use is subject to license terms.
sccli version 2.4.0
built 2007.07.04.17.54
build 22 for solaris-sparc

* inquiry-data
 Vendor: SUN
 Product: StorEdge 3510
 Revision: 421F
 Peripheral Device Type: 0x0
 NVRAM Defaults: 421F 3510 S480F
 Bootrecord version: 1.31H
 Serial Number: 09CACC
 Page 80 Serial Number: 09CACC5FDB326400
 Page 83 Logical Unit Device ID: 600C0FF00000000009CACC5FDB326400
 Page 83 Target Device ID: 206000C0FF09CACC
 IP Address: 192.168.26.218
 Page D0 Fibre Channel Address: A7 (id 40)
 Page D0 Node Name: 206000C0FF09CACC
 Page D0 Port Name: 216000C0FF89CACC
 Ethernet Address: 00:C0:FF:09:CA:CC
 Device Type: Primary
 unique-identifier: 9CACC
 controller-name: "drum"

* network-parameters
 ip-address: 192.168.26.218
 netmask: 255.255.255.0
 gateway: 192.168.26.1
 mode: static
-- etc ---
sccli>  show disks
Ch     Id      Size   Speed  LD     Status     IDs                      Rev
----------------------------------------------------------------------------
 2(3)   6   68.37GB   200MB  ld0    ONLINE     SEAGATE ST373207FSUN72G  055A
                                                   S/N 2331RJA6
                                                  WWNN 20000011C6E4F452
                                                Mirror (2.34)
 2(3)  32   68.37GB   200MB  ld0    ONLINE     FUJITSU MAT3073F SUN72G  0602
                                                   S/N 000512B02J3V
                                                  WWNN 500000E010F9AA00
                                                Mirror (2.35)
 2(3)  33   68.37GB   200MB  ld0    ONLINE     SEAGATE ST373207FSUN72G  055A
                                                   S/N 2331RAT7
                                                  WWNN 20000011C6E4FB27
                                                Mirror (2.36)
 2(3)  34   68.37GB   200MB  ld0    ONLINE     SEAGATE ST373207FSUN72G  055A
                                                   S/N 2431RH9G
                                                  WWNN 20000011C6E4F5FC
                                                Mirror (2.6)
 2(3)  35   68.37GB   200MB  ld0    ONLINE     SEAGATE ST373207FSUN72G  055A
                                                   S/N 2331RFC0
                                                  WWNN 20000011C6E4F756
                                                Mirror (2.32)
 2(3)  36   68.37GB   200MB  ld0    ONLINE     SEAGATE ST373207FSUN72G  055A
                                                   S/N 2431RRA6
                                                  WWNN 20000011C6E4FFCD
                                                Mirror (2.33)
 2(3)  37   68.37GB   200MB  GLOBAL STAND-BY   SEAGATE ST373207FSUN72G  055A
                                                   S/N 2331RE63
                                                  WWNN 20000011C6E4F765
sccli> show inquiry-data
 Vendor: SUN
 Product: StorEdge 3510
 Revision: 421F
 Peripheral Device Type: 0x0
 NVRAM Defaults: 421F 3510 S480F
 Bootrecord version: 1.31H
 Serial Number: 09CACC
 Page 80 Serial Number: 09CACC5FDB326400
 Page 83 Logical Unit Device ID: 600C0FF00000000009CACC5FDB326400
 Page 83 Target Device ID: 206000C0FF09CACC
 IP Address: 192.168.26.218
 Page D0 Fibre Channel Address: A7 (id 40)
 Page D0 Node Name: 206000C0FF09CACC
 Page D0 Port Name: 216000C0FF89CACC
 Ethernet Address: 00:C0:FF:09:CA:CC
 Device Type: Primary
sccli> show network-parameters
 ip-address: 192.168.26.218
 netmask: 255.255.255.0
 gateway: 192.168.26.1
 mode: static
sccli> show port-wwns
Ch  Id   WWPN
-------------------------
 0  40   216000C0FF89CACC
 0  41   216000C0FF99CACC
 1  42   226000C0FFA9CACC
 4  44   256000C0FFC9CACC
 5  47   266000C0FFF9CACC
 5  46   266000C0FFE9CACC
sccli> show redundancy-mode
 Primary controller serial number: 8055321
 Primary controller location: Lower
 Redundancy mode: Active-Active
 Redundancy status: Enabled
 Secondary controller serial number: 8054607
sccli> show ses-devices
Ch  Id Chassis Vendor/Product ID        Rev  PLD  WWNN             WWPN
-------------------------------------------------------------------------------
 2  44 0983DA  SUN StorEdge 3510F A     1103 1000 204000C0FF0983DA 214000C0FF0983DA
                                                     Topology: loop(a)
 3  44 0983DA  SUN StorEdge 3510F A     1103 1000 204000C0FF0983DA 224000C0FF0983DA
                                                     Topology: loop(b)
Back to the main page